Mfg Part Number: KCL-D9A-005 | Alternate P/N: KCLD9A005 | Manufacturer: Lcc Inc |
NSN : 5945-01-409-1947 | NIIN : 014091947 | Item Name : relay electromagnet |
CAGE Code : 58657 | FSC : 5945 Relays and Solenoids |
Thank you for your interest in our available NSN part KCL-D9A-005 on Single Source Purchasing! Our purchasing platform is owned and operated by ASAP Semiconductor, so quality is the cornerstone of our operations. If you are in the market for in-demand Plate Relay Electromagnet parts like KCL-D9A-005 with NSN 5945-01-409-1947, we are your parts procurement partner. Our inventory of over 2 billion new, used, obsolete, and hard-to-find parts comprises only premium items like part number KCL-D9A-005, from trusted manufacturers, such as Lcc Inc, and others. We invite you to browse our catalog until you find a part you wish to procure. Then, simply fill out a Request for Quote form with as much detail as possible, including target prices, shipping deadlines, and desired quantities. Within 15 minutes, our team of experts will contact you with a custom quotation for the NSN part KCL-D9A-005 that fits your needs.
For your ease-of-purchasing, we always list our parts with as much information as possible. For example, you can locate NSN 5945-01-409-1947 alongside the CAGE Code 58657 and the manufacturer Lcc Inc. Furthermore, all parts are shipped alongside their qualifying certifications and manufacturing trace documentation, as applicable. Kick off the parts procurement process today to discover why our loyal customers continuously rely on us to handle their sourcing, logistics management, shipping, and quality management for them so that they can continue to focus on what they do best!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-409-1947 Item Description: Relay Electromagnet | 5945 | 014091947 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Kcl-D9a-005 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.015 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.015 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | CASS STATON, GENERAL ELECTRIC |
AKDX | WINDING QUANTITY | 2 |
APCN | COIL QUANTITY | 2 |
APNA | WINDING DC RESISTANCE RATING | 450.0 OHMS NOMINAL ALL WINDINGS |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 13 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
FEAT | SPECIAL FEATURES | ALL PINS ARE 0.175 IN. LONG. |
TEST | TEST DATA DOCUMENT | 30003-2037AS197 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR |
TTQY | TERMINAL TYPE AND QUANTITY | 13 PIN ALL FUNCTIONS |
![]() |